Gorman-Rupp Pumps 04C52-B 1399307 and up User Manual
Page 27
0 SERIES
OM-01233
MAINTENANCE & REPAIR
PAGE E - 8
IMPELLER
SHAFT
SEAL
PLATE
ROTATING ELEMENT
RETAINER
SPRING
IMPELLER
ADJUSTING
SHIMS
IMPELLER
BELLOWS
SHAFT
SLEEVE
O‐RING
STATIONARY
SEAT
SPRING
CENTERING
WASHER
Figure 2. Seal Assembly
This seal is not designed for operation at
temperatures above 160
_F (71_C). Do not
use at higher operating temperatures.
Position the seal plate (12) on a flat surface with the
impeller side facing up. If the wear ring (13) was re
moved, press the replacement ring into the seal
plate until it seats squarely against the bore shoul
der.
The wear ring must seat squarely in the
seal plate bore or binding and/or exces
sive wear will result.
Subassemble the O‐ring onto the stationary ele
ment and use even pressure to press this subas
sembly into the seal plate until it seats squarely
against the shoulder bore
Carefully slide the assembled seal plate and sta
tionary seal element over the shaft. Use caution not
to nick or damage the stationary seat on the shaft
threads. Temporarily secure the seal plate to the
pedestal (14) using two capscrews and nuts (1/2
UNC X 1 1/2 inch long, not supplied).
Lubricate the I.D. of the bellows with water, and
slide the rotating portion of the seal over the shaft
sleeve until the seal face is just flush with the un
dercut end of the sleeve.
Slide the assembled shaft sleeve and rotating por
tion of the seal onto the shaft until the polished
faces contact. Continue to push the sleeve through
the seal until it is fully seated against the shaft
shoulder.
Install the seal spring and spring centering washer
(40).
Impeller Installation
Inspect the impeller and replace it if cracked or
badly worn.
For maximum pump efficiency, the impeller should
be centered within the volute scroll.