beautypg.com

Gorman-Rupp Pumps 04C3-B 407671 and up User Manual

Page 27

background image

OM-01218

0 SERIES

MAINTENANCE & REPAIR

PAGE E - 7

Heat the bearings to a uniform temperature no
higher than
250

_F (120_C), and slide the bearings

onto the shaft, one at a time, until they are fully
seated against the shaft shoulders. This should be
done quickly, in one continuous motion, to prevent
the bearings from cooling and sticking on the shaft.

After the bearings have been installed and allowed
to cool, check to ensure that they have not moved
away from the shaft shoulders in shrinking. If
movement has occurred, use a suitably sized
sleeve and a press to reposition the bearings
against the shaft shoulders.

If heating the bearings is not practical, use a suit­
ably sized sleeve and an arbor (or hydraulic) press
to install the bearings on the shaft.

When installing the bearings onto the
shaft, never press or hit against the outer
race, balls, or ball cage. Press only on the
inner race.

Slide the shaft and assembled bearings into the
pedestal until the inboard bearing is fully seated
against the bore shoulder.

When installing the shaft and bearings into
the bearing bore, push against the outer
race. Never hit the balls or ball cage.

Install the same thickness of bearing adjusting
shims (18) as previously removed and secure the
bearing cap (19) to the pedestal with the hardware
(20 and 21).

Shaft endplay should be between .002 and .010
inch (0,05 to 0,25 mm). Check the shaft endplay
and add or remove bearing adjusting shims as re­
quired to achieve the correct endplay.

Reinstall the slinger ring (14).

Lubricate the pedestal as indicated in LUBRICA­
TION
.

Seal Reassembly and Installation

(Figures 1 and 3)

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent.

Most cleaning solvents are toxic and
flammable. Use them only in a well ven­
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain­
ers.

The seal is not normally reused because wear pat­
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer­
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.

Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non‐oil based solvent and a clean, lint‐free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.

Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak­
age. If any components are worn, replace the com­
plete seal; never mix old and new seal parts.

If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.

To ease installation of the seal, lubricate the bel­
lows and O‐rings with water or a very small
amount of light lubricating oil, and apply a drop of
light lubricating oil on the finished faces. Assemble
the seal as follows (see Figure 2).