beautypg.com

Gorman-Rupp Pumps 03A20-B 751140 and up User Manual

Page 25

background image

0 SERIES

OM-01175

MAINTENANCE & REPAIR

PAGE E - 6

Most cleaning solvents are toxic and
flammable. Use them only in a well ven­
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain­
ers.

Clean the bearings thoroughly in fresh cleaning
solvent. Dry the bearings with filtered compressed
air and coat with light oil.

Bearings must be kept free of all dirt and
foreign material. Failure to do so will great­
ly shorten bearing life. Do not spin dry
bearings. This may scratch the balls or
races and cause premature bearing fail­
ure.

Rotate the bearings by hand to check for rough­
ness or binding and inspect the bearing balls. If ro­
tation is rough or the bearing balls are discolored,
replace the bearings.

The bearing tolerances provide a tight press fit
onto the shaft and a snug slip fit into the pedestal.
Replace the bearings, shaft, or pedestal if the
proper bearing fit is not achieved.

If bearing replacement is required, remove the out­
board bearing retaining ring (28) and use a suit­
able bearing puller to remove the bearings from the
shaft.

Shaft And Bearing Reassembly And
Installation

Clean the pedestal, shaft and all component parts
(except the bearings) with a soft cloth soaked in
cleaning solvent. Inspect the parts for wear or dam­
age as necessary.

Most cleaning solvents are toxic and

flammable. Use them only in a well ven­
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain­
ers.

Inspect the shaft for distortion, nicks or scratches,
or for thread damage on the impeller end. Dress
small nicks and burrs with a fine file or emery cloth.
Replace the shaft if defective.

Position the oil seal (20) in the bearing cap (19) with
the lip positioned as shown in Figure 1. Press the
oil seal into the bearing cap until the face is just
flush
with the interior surface of the bearing cap.

Apply a thin film of “Loctite No. 515 Gasket Elimina­
tor” (or equivalent compound) to the face of the
bearing cap (19) and secure the cap to the pedes­
tal with hardware (17 and 18).

To prevent damage during removal from
the shaft, it is recommended that bearings
be cleaned and inspected in place. It is
strongly recommended that the bearings
be replaced any time the shaft and bear­
ings are removed.

The bearings may be heated to ease installation.
An induction heater, hot oil bath, electric oven, or
hot plate may be used to heat the bearings. Bear­
ings should never be heated with a direct flame or
directly on a hot plate.

NOTE

If a hot oil bath is used to heat the bearings, both the
oil and the container must be absolutely clean. If
the oil has been previously used, it must be thor­
oughly
filtered.

NOTE

When installing the bearings, position the outboard
bearing (23) on the shaft with the integral retaining
ring on the bearing O.D. toward the drive end of the
shaft.

Heat the bearings to a uniform temperature no
higher than
250

_F (120_C), and slide the bearings