OM−01527

80 SERIES

OPERATION

PAGE C − 4

Checking bearing temperatures by hand is inaccu-
rate. Bearing temperatures can be measured ac-
curately by placing a contact-type thermometer
against the housing. Record this temperature for
future reference.

A sudden increase in bearing temperatures is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing

lubricant is of the proper viscosity and at the cor-
rect level (see LUBRICATION in Section E). Bear-
ing overheating can also be caused by shaft
misalignment and/or excessive vibration.

When pumps are first started, the bearings may
seem to run at temperatures above normal. Con-
tinued operation should bring the temperatures
down to normal levels.