OM-00830
80 SERIES
MAINTENANCE & REPAIR
PAGE E - 9
This seal is not designed for operation at
temperatures above 160
_F (71_C). Do not
use at higher operating temperatures.
Position the seal plate (32) on a flat surface with the
impeller side down. Position the lip seal (7) in the
seal plate bore with the lip position as shown in Fig
ure 1. Press the lip seal into the seal plate bore until
fully seated.
Position the seal plate on a flat surface with the im
peller side facing up. Lubricate the stationary seat
O‐ring with water or light oil, and press the station
ary subassembly into the seal plate until fully
seated. After installation, wipe the face of the sta
tionary element lightly in a concentric pattern with a
clean, lint‐free tissue.
Slide the assembled seal plate and stationary seat
over the impeller shaft (20) and temporarily secure
the seal plate to the pedestal (12) using two cap
screws and nuts (1/2 UNC X 1 1/2 inch long, not
supplied).
Lubricate the O.D. of the shaft sleeve with water or
a very small amount of oil, and slide the rotating
portion of the seal assembly (consisting of the ro
tating element, bellows and retainer) onto the shaft
sleeve until the face of the rotating element is just
flush with the chamfered end of the sleeve.
Slide the assembled seal and sleeve onto the shaft
until the seal faces contact. Continue to press the
shaft sleeve through the rotating portion of the seal
until it is fully seated against the shaft shoulder. Use
caution not to roll or damage the lip of the seal (7).
Install the seal spring and spring centering washer
(8).
Lubricate the seal as indicated in LUBRICATION
at the end of this section.
Impeller Installation and Adjustment
Inspect the impeller, and replace it if cracked or
badly worn. Install the same thickness of impeller
shims (9) as previously removed, and screw the
impeller onto the shaft until tight.
A clearance of .010 to .020 inch (0,25 to 0,51 mm)
between the impeller and the seal plate is neces
sary for maximum pump efficiency. Measure this
clearance and add or remove impeller shims until
this clearance is reached.
NOTE
Be sure the seal plate is tight against the pedestal
while measuring this clearance.
After the back clearance is set, secure the impeller
with the hardware (35, 36 and 37). Reinstall the
bottle oiler and piping (4, 5 and 6).
Pump Casing Installation
If the wear plate assembly (34) was removed, posi
tion the replacement wear plate assembly squarely
against the casing shoulder and secure it with the
mounting hardware (38, 39, 41 and 42). Replace
the fiber washer (42) if badly worn or compressed.
Remove the hardware temporarily securing the
seal plate to the pedestal. Install the same thick
ness of pump casing gaskets (33) as previously re
moved. Secure the pump casing (1) to the seal
plate and pedestal with the nuts (31). Do not fully
tighten the nuts at this time.
A clearance of .008 to .015 inch (0,20 to 0,38 mm)
between the impeller and the wear plate is also rec
ommended for maximum pump efficiency. Set this
clearance by adding or removing gaskets in the
pump casing gasket set (33) until the impeller
scrapes against the wear plate when the shaft is
turned by hand. After the impeller scrapes, add ap
proximately .008 inch (0,20 mm) of gaskets.
Secure the pump casing to the base with the pre
viously removed hardware. Be sure to reinstall any
leveling shims used under the mounting feet of the
pump casing.
If a lifting eye was used to move the pump casing,
be sure to remove the lifting eye from the pump
casing.
Do not attempt to lift the complete pump
unit using the lifting eye. It is designed