Lubrication – Gorman-Rupp Pumps 83A2-B 732174 and up User Manual
Page 31
80 SERIES
OM−00856
MAINTENANCE & REPAIR
PAGE E − 10
LUBRICATION
Seal Assembly
Fill the grease cup (9) through the grease fitting
with No. 2 lithium base grease until grease es-
capes from the relief hole. Turn the grease cup arm
counterclockwise until it is at the top of the stem;
this will release the spring to apply grease to the
seal (see Figure 4).
GREASE
FITTING
CROSS
ARM
POSITION
WHEN
EMPTY
POSITION
FOR
FILLING
POSITION
WHEN
IN USE
RELIEF
HOLE
Figure 4. Automatic Lubricating Grease Cup
NOTE
Some smoking and leakage may occur after instal-
ling a new seal assembly. This should stop after the
pump has run a while and the lapped seal faces
have seated in.
Bearings
The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly
through the sight gauge (26) and maintain it at the
middle of the gauge. When lubrication is required,
add SAE No. 30 non-detergent oil through the hole
for the air vent (14). Do not over-lubricate. Over-lu-
brication can cause the bearings to over-heat, re-
sulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.
Under normal conditions, change the oil each
5000 hours or once each year, more frequently if
the pump is operated continuously or installed in
an environment with rapid temperature change.
Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Power Source
Consult the literature supplied with the power
source, or contact your local power source repre-
sentative.