beautypg.com

Gorman-Rupp Pumps 83C2-B 814600 and up User Manual

Page 29

background image

80 SERIES

OM−00879

MAINTENANCE & REPAIR

PAGE E − 8

non-oil based solvent and a clean, lint-free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.

Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak-
age. Clean and polish the shaft sleeve, or replace it
if there are nicks or cuts on either end. If any com-
ponents are worn, replace the complete seal;
never mix old and new seal parts.

If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.

To ease installation of the seal, lubricate the seal
liner (54) with water or a very small amount of oil,
and apply a drop of light lubricating oil on the fin-
ished faces. Assemble the seal as follows, (see Fig-
ure 3).

IMPELLER

SHAFT

STATIONARY

SEAT

STATIONARY

WASHERS

ROTATING

ELEMENT

IMPELLER

SHIMS

ROTATING

ELEMENT

SEAL PLATE

SPRING

IMPELLER

SPACER

SLEEVE

PACKING RINGS

SEAL LINER

STATIONARY

SEAT

Figure 3. Seal Assembly

This seal is not designed for operation at
temperatures above 110

_F (43_C). Do not

use at higher operating temperatures.

Before installing the seal, inspect the bore of the
seal liner (54) for wear or grooves which might
cause leakage or damage to the seal packing
rings. If the seal liner requires replacement, re-
move the seal plate assembly as described in Seal
Removal And Disassembly, and position it on the
bed of an arbor (or hydraulic) press. Use a new

sleeve to force the old one out. After the new liner is
properly installed, a 1/4-inch (6,4 mm) diameter
hole must be drilled through it to permit the flow of
lubricant to the seal assembly. Be careful to center
the drill in the threaded grease piping hole and not
damage the threads. Deburr the hole from the in-
side of the seal liner after drilling.

Before installing the seal, lubricate the seal liner
with water or a very small amount of oil, and apply
a drop of light lubricating oil on the finished faces.

Slide the seal plate assembly over the impeller
shaft (24) and temporarily secure the seal plate to
the pedestal (15) using two capscrews and nuts
(3/8−16 UNC x 1−1/2 inch long, not supplied).