Gorman-Rupp Pumps 84A52-B 1325165 and up User Manual
Page 29
OM−00924
80 SERIES
MAINTENANCE & REPAIR
PAGE E − 8
Press the bearing retainer into the pedestal until it
seats against the bearing. Be careful not to cut the
oil seal lip on the shaft keyway. Be sure the ma-
chine screws and lockwashers (27 and 28) in the
bearing retainer are positioned horizontally inline.
Reinstall the retaining ring (22) and check shaft
endplay.
NOTE
Shaft endplay should be .002 to .010 inch (0,05 to
0,25 mm). Add or remove bearing adjusting shims
to obtain the correct endplay.
Install the slinger ring (35) and shaft key (25). Install
any leveling shims used under the pedestal feet.
Seal Reassembly and Installation
(Figures 1 and 3)
Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent.
Most cleaning solvents are toxic and
flammable. Use them only in a well-ven-
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain-
ers.
The seal is not normally reused because wear pat-
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer-
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.
Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non-oil based solvent and a clean, lint-free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.
Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak-
age. Clean and polish the shaft sleeve, or replace it
if there are nicks or cuts on either end. If any com-
ponents are worn, replace the complete seal;
never mix old and new seal parts.
If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter. Discard the spring centering washer in-
cluded with the seal. It is not used in this applica-
trion.
To ease installation of the seal, lubricate the bel-
lows, sleeve and stationary seat O-ring with water
or a very small amount of light lubricating oil, and
apply a drop of light lubricating oil on the finished
faces. Assemble the seal as follows (see Figure 3).