Gorman-Rupp Pumps 84A3-B 818301 and up User Manual
Page 12
80 SERIES
OM−00923
PAGE B − 5
INSTALLATION
rod in order to eliminate electrostatic build-up by
the liquid being pumped. Install the ground rod in
accordance with the National Electrical Codes and
all local codes. Be sure the fastening device makes
a tight electrical connection with the rod and the
pump.
Inspect and test the ground wire assembly
for conductivity. replace broken or frayed
wire before resuming operation.
ALIGNMENT
The alignment of the pump and its power source is
critical for trouble-free mechanical operation. In
either a flexible coupling or V-belt driven system,
the driver and pump must be mounted so that their
shafts are aligned with and parallel to each other. It
is imperative that alignment be checked after the
pump and piping are installed, and before opera-
tion.
NOTE
Check Rotation, Section C, before final alignment
of the pump.
When mounted at the Gorman-Rupp factory, driver
and pump are aligned before shipment. Misalign-
ment will occur in transit and handling. Pumps
must be checked and realigned before operation.
Before checking alignment, tighten the foundation
bolts. The pump casing feet and/or pedestal feet,
and the driver mounting bolts should also be tightly
secured.
When checking alignment, disconnect
the power source to ensure that the
pump will remain inoperative.
Adjusting the alignment in one direction
may alter the alignment in another direc-
tion. check each procedure after altering
alignment.
Coupled Drives
When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer’s service literature.
Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90 de-
grees. The coupling is in alignment when the hub
ends are the same distance apart at all points (see
Figure 3A).
Figure 3A. Aligning Spider Type Couplings
Figure 3B. Aligning Non-Spider Type
Couplings
Align non-spider type couplings by using a feeler
gauge or taper gauge between the coupling halves
every 90 degrees. The coupling is in alignment
when the hubs are the same distance apart at all
points (see Figure 3B).
Check parallel adjustment by laying a straightedge
across both coupling rims at the top, bottom, and