Gorman-Rupp Pumps 86B2-B 819132 and up User Manual
Page 26
OM-00965
80 SERIES
MAINTENANCE & REPAIR
PAGE E - 5
wise until it rests against the cover (see Figure 4) to
prevent the grease in the cup from escaping. Re
move the grease cup and piping (11, 12, 13, 14
and 15).
Immobilize the impeller by wedging a block wood
between the vanes. Remove the impeller caps
crew, lock washer and washer (41, 42 and 43). If
removed, install the shaft key (28). Install a lathe
dog on the drive end of the shaft (29) with the “V”
notch positioned over the shaft keyway.
With the impeller rotation still blocked, strike the
lathe dog sharply in a counterclockwise direction
(when facing the drive end of the shaft). The impel
ler may also be loosened by using a long piece of
heavy bar stock to pry against the arm of the lathe
dog in a counterclockwise direction (when facing
the drive end of the shaft) as shown in Figure 2.
Use caution not to damage the shaft or keyway.
When the impeller breaks loose, remove the lathe
dog and wood block and unscrew the impeller
from the shaft.
Turn
Counterclockwise
Lathe Dog Arm
“V” Notch
Shaft Key
Impeller Shaft
Lathe Dog
Setscrew
Heavy
Bar Stock
Figure 2. Loosening Impeller
Unscrew the impeller from the shaft. Use caution
when removing the impeller; tension on the seal
spring will be released as the impeller is un
screwed.
Inspect the impeller and replace it if cracked or
badly worn. Slide the impeller adjusting shims (63)
and seal washer (66) off the impeller shaft. Tie and
tag the shims, or measure and record their thick
ness for ease of reassembly.
Seal Removal and Disassembly
Remove the outer rotating element. Slide the seal
plate, shaft sleeve, and remaining seal parts off the
shaft as a unit. Carefully remove the stationary and
rotating seal elements, packing rings and wash
ers, seal spring and spacer sleeve from the seal
plate.
Inspect the seal plate and replace it if cracked or
badly worn. Inspect the seal liner (67) for wear or
grooves that could cause leakage or damage to
the seal packing rings. The seal liner is a press fit
into the seal plate and does not normally require re
placement. If replacement is required, see Seal
Installation.
Shaft And Bearing Removal And Disassembly
When the pump is properly operated and main
tained, the pedestal should not require disassem
bly. Disassemble the shaft and bearings only
when there is evidence of wear or damage.
Shaft and bearing disassembly in the field
is not recommended. these operations
should be performed only in a properly‐
equipped shop by qualified personnel.
Remove the pedestal drain plug (35) and drain the
pedestal. Clean and reinstall the plug.
Remove the slinger ring (38) from the shaft. Re
move the pedestal mounting hardware from the
base. Tie and tag any shims used under the
mounting feet for leveling.
Use snap ring pliers to remove the bearing retain
ing ring (25) from the pedestal bore. Remove the
bearing shim set (24); tie and tag the shims, or
measure and record their thickness for ease of
reassembly.
Loosen. but do not remove, the two machine
screws (30) in the bearing retainer (26) and pry the
retainer from the pedestal bore using a pair of