PAGE E − 9
stationary seat O-ring with light oil and press the
stationary seat into the seal plate bore until fully
seated.
Slide the assembled seal plate and stationary por-
tion of the seal over the shaft and secure the seal
plate to the pedestal using the two machine
screws.
Subassemble the rotating element into the retainer
and bellows, then slide this subassembly onto the
shaft sleeve (12) until the face of the rotating ele-
ment is just flush with the chamfered end of the
sleeve.
Slide the assembled seal and shaft sleeve onto the
shaft until the seal faces contact. Continue to push
the sleeve through the seal until the chamfered end
seats firmly against the shaft shoulder.
Install the seal spring and spring centering washer.
Impeller Installation
Inspect the impeller and replace it if cracked or
badly worn.
The shaft and impeller threads must be
completely clean before reinstalling the im-
peller. Even the slightest amount of dirt on
the threads can cause the impeller to seize
to the shaft, making future removal difficult
or impossible without damage to the im-
peller or shaft.
Install the same thickness of impeller shims (10) as
previously removed and screw the impeller onto
the shaft until tight.
Make sure the seal spring seats
squarely over the step on the back of the impeller.
The clearance between the back of the impeller
and the seal plate should be between 0.020 and
0.040 inch (0,51 to 1,02 mm). Measure this clear-
ance and add or remove shims from the impeller
adjusting shim set until the correct clearance is
achieved.
Pump Casing and Wear Plate Installation
If the wear plate (41) was removed, install the new
wear plate in the pump casing and secure it with
the hardware (43 and 44).
Install a new set of casing gaskets (10) and slide
the pump casing over the impeller and against the
gaskets. The clearance between the face of the im-
peller and the wear plate should be between .008
and .015 inch (0,20 to 0,38 mm). Remove gaskets
from the gasket set until the correct clearance is
achieved. Secure the pump casing to the seal plate
and pedestal with the nuts (39).
Suction Check Valve Installation
Inspect the check valve components and replace
them as required. Subassemble the check valve
weights (57 and 59) and gasket (58) using the at-
taching hardware (55 and 56).
Install the check valve assembly in the valve seat
(60). Replace the seat gasket (61), and secure the
valve seat to the suction port using the round head
machine screws (53). Replace the suction flange
gasket (49), and secure the suction flange (50) to
the seat with the nuts (52).
Check the operation of the check valve to ensure
proper seating and free movement.
Final Pump Reassembly
Be sure all hardware and drain plugs are tight, and
that the pump is secure to the base and power
source.
Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, and that the weight of the lines is indepen-
dently supported and secure.
Before starting the pump, fill the pump casing with
clean liquid. Apply Never-Seez" or equivalent
compound to the fill plug (7). Reinstall and tighten
the fill plug.
Refer to OPERATION, Section C, before putting
the pump back into service.