beautypg.com

Gorman-Rupp Pumps 81 1/2D3-E.50 1P 262113 and up User Manual

Page 15

background image

OM−00750

80 SERIES

OPERATION

PAGE C − 3

After stopping the pump, disconnect the incoming
power to the motor and lock it out to ensure that the
pump will remain inoperative.

Cold Weather Preservation

In below freezing conditions, drain the pump to
prevent damage from freezing. Also, clean out any
solids by flushing with a hose. Operate the pump
for approximately one minute; this will remove any

remaining liquid that could freeze the pump rotat-
ing parts. If the pump will be idle for more than a
few hours, or if it has been pumping liquids con-
taining a large amount of solids, drain the pump,
and flush it thoroughly with clean water. To prevent
large solids from clogging the drain port and pre-
venting the pump from completely draining, insert
a rod or stiff wire in the drain port, and agitate the
liquid during the draining process. Clean out any
remaining solids by flushing with a hose.