OM−00769
80 SERIES
PAGE B − 5
INSTALLATION
NOTE
The bypass line may clog frequently if the liquid
contains solids and the valve remains closed. If this
condition occurs, either use a larger bypass line or
leave the shut-off valve open during pumping.
ELECTRICAL CONNECTIONS
This pump is driven by an electric motor. Check
that the electrical service available matches the
motor requirements stamped on the motor name-
plate before connecting the motor to the incoming
power.
The electrical power used to operate the
pump is high enough to cause injury or
death. Obtain the services of a qualified
electrician to make all electrical con-
nections.
Do not install and operate a non-explo-
sion proof motor in an explosive atmo-
sphere. Install, connect, and operate
the motor in accordance with The Na-
tional Electric Code and all local codes.
If there is a conflict between the instruc-
tions in the manual accompanying the
unit and The National Electric Code or
the applicable local code, The National
or local code shall take precedence.
Refer to the following motor data before making
electrical connections.
VOLTAGE
PHASE
HP
Hz
RPM
F.L. AMPS
115/230
1
60
3450
15.4/7.7
MODEL
81 1/2E3−X1.5 1P
1.5
GROUNDING
Because this pump is used to handle volatile or
flammable liquids, the unit must be grounded by
attaching a ground wire assembly to a ground rod
in order to eliminate electrostatic build-up by the
liquid being pumped. Install the ground rod in ac-
cordance with the National Electrical Codes and all
local codes. Be sure the fastening device makes a
tight electrical connection with the rod and the
pump.
Inspect and test the ground wire assembly
for conductivity. Replace a broken or
frayed wire before resuming operation.