beautypg.com

Operation - section c – Gorman-Rupp Pumps 81 1/2E52-B 1271304 and up User Manual

Page 13

background image

OM−00791

80 SERIES

OPERATION

PAGE C − 1

OPERATION − SECTION C

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and
decals attached to the pump.

This pump is designed to handle most
non-volatile, non-flammable liquids
containing specified entrained solids.
Only the Gorman-Rupp Company or an
authorized Gorman-Rupp distributor
may modify a pump or approve its use
for handling volatile, flammable liquids.
If the pump is used for handling volatile,
flammable liquids, all drivers and/or
controls must meet industry standards
and codes for use in an explosive atmo-
sphere. Do not attempt to pump liquids
for which the pump, driver and/or con-
trols have not been approved, or which
may damage the pump or endanger per-
sonnel as a result of pump failure.

If this pump has been approved for use
with volatile and/or flammable liquids,
be certain proper safety practices are
followed before operating or servicing
the pump. Provide adequate ventilation,
prohibit smoking, wear static-resistant
clothing and shoes. Clean up all fuel
spills immediately after occurrence.

Pump speed and operating condition
points must be within the continuous per-
formance range shown on the curve (See
Section E, Page 1).

PRIMING

Install the pump and piping as described in IN-
STALLATION. Make sure that the piping connec-
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri-
cated (see LUBRICATION in MAINTENANCE
AND REPAIR).

This pump is self-priming, but the pump should
never be operated unless there is liquid in the
pump casing.

Never operate this pump unless there is
liquid in the pump casing. The pump will
not prime when dry. Extended operation of
a dry pump will destroy the seal assembly.

Add liquid to the pump casing when:

1. The pump is being put into service for the

first time.

2. The pump has not been used for a consider-

able length of time.

3. The liquid in the pump casing has evapo-

rated.

Once the pump casing has been filled, the pump
will prime and reprime as necessary.

After filling the pump casing, reinstall
and tighten the fill plug. Do not attempt
to operate the pump unless all connect-
ing piping is securely installed. Other-
wise, liquid in the pump forced out un-
der pressure could cause injury to per-
sonnel.

To fill the pump, remove the pump casing fill cover
or fill plug in the top of the casing, and add clean
liquid until the casing is filled. Replace the fill cover
or fill plug before operating the pump.