OM-00670

10 SERIES

MAINTENANCE & REPAIR

PAGE E - 10

Impeller Installation and Adjustment

Inspect the impeller and replace it if cracked or
badly worn. Install the same thickness of impeller
shims (73) as previously removed, and screw the
impeller onto the shaft until tight.

A clearance of .020 to .040 inch (0,51 to 1,02 mm)
between the impeller and the seal plate is neces­
sary for maximum pump efficiency. Measure this
clearance and add or remove impeller shims until
this clearance is reached.

NOTE

Be sure the seal plate is tight against the pedestal
while measuring this clearance.

Install the automatic grease cup and piping (69, 70
and 71) in the seal plate. After the pump casing is
installed, lubricate the seal assembly as indicated
in LUBRICATION.

Pump Casing Installation

Remove the hardware temporarily securing the
seal plate to the pedestal. Install the same thick­
ness of pump casing gaskets (26) as previously re­
moved. Secure the pump casing (1) to the seal
plate and pedestal with the nuts (24). Do not fully
tighten the nuts at this time.

NOTE

The back cover assembly (34) must be in place to
adjust the impeller face clearance.

A clearance of .010 to .020 inch (0,24 to 0,48 mm)
between the impeller and the wear plate (27) is also
recommended for maximum pump efficiency. Set
this clearance by adding or removing gaskets in
the pump casing gasket set (26) until the impeller
scrapes against the wear plate when the shaft is
turned by hand. After the impeller scrapes, add ap­
proximately .010 inch (0,24 mm) of gaskets.

After the face clearance has been set, tighten the
nuts (24) securing the pump casing to the pedes­
tal.

Secure the pump casing to the base with the pre­
viously removed hardware. Be sure to reinstall any

leveling shims used under the mounting feet of the
pump casing.

Suction Check Valve Installation

Inspect the check valve assembly (42) and replace
it if badly worn.

NOTE

The check valve assembly must be replaced as a
complete unit. Individual parts are not sold sepa­
rately.

Reach through the back cover opening with the as­
sembled check valve, and position the check valve
adaptor in the mounting slot in the suction flange.
Align the adaptor with the flange hole and secure
the assembly with the check valve pin (52).

NOTE

If the suction flange was removed, replace the gas­
ket (53), and apply `Permatex Aviation No. 3 Form‐
A‐Gasket' or equivalent compound to the mating
surfaces.

Back Cover Installation

If the wear plate (27) was removed for replace­
ment, secure it to the cover plate (34) using the at­
taching hardware (29 and 30) at this time. The wear
plate must be concentric to prevent binding when
the back cover is installed.

Clean any scale or debris from the contacting sur­
faces on the pump casing that might prevent a
good seal with the back cover. Replace the back
cover gasket (39) and slide the back cover assem­
bly into the pump casing. Be sure the wear plate
does not bind against the impeller.

NOTE

To ease future disassembly, apply a film of grease
or `Never‐Seez' on the back cover shoulder, or any
surface that contacts the pump casing. This action
will reduce rust and scale build‐up.

Secure the back cover assembly by installing the
clamp bar (31) and tightening the clamp bar screw
(32). Do not over‐tighten the clamp bar screw; it
should be just tight enough to seal the back cover
shoulder.