Gorman-Rupp Pumps 14C20-F3L 1319349 and up User Manual
Page 17
OM−03413
10 SERIES
OPERATION
PAGE C − 3
Open the suction line, and read the vacuum gauge
with the pump primed and at operation speed.
Shut off the pump. The vacuum gauge reading will
immediately drop proportionate to static suction
lift, and should then stabilize. If the vacuum reading
falls off rapidly after stabilization, an air leak exists.
Before checking for the source of the leak, check
the point of installation of the vacuum gauge.
STOPPING
Never halt the flow of liquid suddenly. If the liquid
being pumped is stopped abruptly, damaging
shock waves can be transmitted to the pump and
piping system. Close all connecting valves slowly.
On engine driven pumps, reduce the throttle
speed slowly and allow the engine to idle briefly be-
fore stopping.
Stopping
Reduce the throttle speed slowly, and allow the en-
gine to idle briefly before switching the HAND-OFF-
AUTO switch to ‘OFF’.
If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.
After stopping the pump, close and lock the control
panel cover, or disconnect the positive battery
cable to ensure that the pump will remain inopera-
tive.
Safety Shutdown System
The unit is equipped with a safety system to auto-
matically shut down the engine under certain con-
ditions. The engine will automatically shut down:
1. If the engine exceeds its safe operating tem-
perature.
2. If the engine oil pressure drops below design
limits.
3. If the engine fails to start within a pre-set peri-
od of time.
4. If the engine speed exceeds the safe operat-
ing range.
5. If the engine fan belt breaks.
Lights on the control panel will indicate which of the
safety features has caused the engine to shut
down.
Should any of the safety features cause the engine
to shut down, the cause must be determined and
corrected before putting the unit back into service.
The engine will not restart until the HAND-OFF-
AUTO switch has been returned to the ‘OFF’ posi-
tion for at least 10 seconds.
All safety shutdown features are pre-set at the fac-
tory for optimum performance and safety; do not
attempt to adjust these settings.
Never disconnect any of the safety shut-
down features; this will void the warran-
ty and could result in serious damage to
the unit and/or injury to personnel. Safe-
ty shutdown features are pre-set at the
factory; do not attempt to adjust any of
the settings. Determine the cause of
shutdown before putting the unit back
into service. Consult the factory for ad-
ditional information.
OPERATION IN EXTREME HEAT
The safety shutdown system will automatically
stop the unit if engine operating temperature ex-
ceeds design limits. If engine over-temperature
shutdown occurs, allow the unit to cool before re-
starting.
If engine overheating continues, check the engine
lubricant level and viscosity. Consult the engine
operation manual for the recommended lubricant
for operation in extreme heat.
If the unit is equipped with the optional auto-start
control, the float(s) may need to be adjusted to al-
low shorter run and longer cooling periods, if pos-
sible.