beautypg.com

Gorman-Rupp Pumps 16A2-F3L 1317807 and up User Manual

Page 39

background image

10 SERIES

OM−00698

MAINTENANCE & REPAIR

PAGE E − 16

NOTE

The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.

Under normal conditions, drain the intermediate
once each year and refill with approximately 7−1/2
ounces (22 ml) of clean oil. Change the oil more fre-
quently if the pump is operated continuously or in-
stalled in an environment with rapid temperature
change.

Monitor the condition of the bearing lubri-

cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the power
source, or contact your local Deutz engine repre-
sentative.