PAGE D - 2

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP REQUIRES
TOO MUCH
POWER

PUMP CLOGS
FREQUENTLY

Impeller or other wearing parts worn
or damaged.

Replace worn or damaged parts.
Check that impeller is properly
centered and rotates freely.

Impeller clogged.

Free impeller of debris.

Pump speed too slow.

Check driver output; check belts
or couplings for slippage.

Discharge head too high.

Install bypass line.

Suction lift too high.

Measure lift w/vacuum gauge. Re­
duce lift and/or friction losses in
suction line.

Pump speed too high.

Check driver output; check that
sheaves or couplings are cor­
rectly sized.

Discharge head too low.

Adjust discharge valve.

Liquid solution too thick.

Dilute if possible.

Bearing(s) frozen.

Disassemble pump and check
bearing(s).

Liquid solution too thick.

Dilute if possible.

Discharge flow too slow.

Open discharge valve fully to in­
crease flow rate, and run power
source at maximum governed
speed.

Suction check valve or foot valve
clogged or binding.

Clean valve.

PUMP STOPS OR
FAILS TO DELIVER
RATED FLOW OR
PRESSURE

Air leak in suction line.

Lining of suction hose collapsed.

Correct leak.

Replace suction hose.

Leaking or worn seal or pump gasket.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Strainer clogged.

Check strainer and clean if neces­
sary.

Suction intake not submerged at
proper level or sump too small.

Check installation and correct sub­
mergence as needed.