INSTALLATION
tems using two or more belts, make certain that the
belts are a matched set; unmatched sets will cause
accelerated belt wear.
MISALIGNED:
SHAFTS
NOT PARALLEL
MISALIGNED:
SHAFTS
NOT IN LINE
ALIGNED: SHAFTS
PARALLEL AND
SHEAVES IN LINE
Figure 6. Alignment of V‐Belt Driven Pumps
Tighten the belts in accordance with the belt manu
facturer's instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra
tio; overspeeding the pump may damage both
pump and power source.
Do not operate the pump without the
guard in place over the rotating parts
.
exposed rotating parts can catch cloth
ing, fingers, or tools, causing severe in
jury to personnel.
DRIVE BELT TENSIONING
General Rules of Tensioning
For new drive belts, check the tension after 5, 20
and 50 hours of operation and re‐tension as re
quired (see the following procedure for measuring
belt tension). Thereafter, check and re‐tension if re
quired monthly or at 500 hour intervals, whichever
comes first.
Ideal drive belt tension is the lowest tension at
which the belt will not slip under peak load condi
tions. Do not over‐tension drive belts. Over‐ten
sioning will shorten both drive belt and bearing life.
Under‐tensioning will cause belt slippage. Always
keep belts free from dirt, grease, oil and other for
eign material which may cause slippage.