Troubleshooting - section d – Gorman-Rupp Pumps 83B52-GX390 1324570 and up User Manual
Page 16
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO
PRIME
Strainer clogged.
Check strainer and clean if neces-
sary.
Suction lift or discharge head too high.
Check piping installation and install
bypass line if needed. See INSTAL-
LATION.
Leaking or worn seal or pump gasket.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Lining of suction hose collapsed.
Replace suction hose.
Air leak in suction line.
Correct leak.
Suction check valve or foot valve
clogged or binding.
Clean valve.
Not enough liquid in casing.
Add liquid to casing. See PRIMING.
Suction check valve contaminated or
damaged.
Clean or replace check valve.
OM−04738
80 SERIES
TROUBLESHOOTING
PAGE D − 1
TROUBLESHOOTING − SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this manual.
2. Shut down the engine and discon-
nect the spark plug wire to ensure
that the pump will remain inopera-
tive.
3. Allow the pump to completely cool if
overheated.
4. Check the temperature before open-
ing any covers, plates, or plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cautiously.
7. Drain the pump.