Gorman-Rupp Pumps 02F1-GR 642659 and up User Manual
Page 34
0 SERIES
OM-01155
MAINTENANCE & REPAIR
PAGE E - 14
(7), which are shipped loose. The air vent
must be installed to prevent the gearbox
from overheating during operation.
The gearbox assembly was lubricated and
tested before it was shipped from the facto
ry; however, the lubricant level must be
checked before putting the pump into ser
vice.
Change the lubricant in a new gearbox after an ini
tial break‐in period of 24 hours, and before 100
hours of operation. The lubricant should be
changed while the pump is at operating tempera
ture. Remove the gearbox drain plug to drain the
gearbox.
Add 2 ounces (0,1 liter) of Dow Corning `Molykote
r
M Gear Guard' to the gearbox, then top off with ap
proximately 20 ounces (591 ml) of premium quali
ty, multi‐purpose, extreme pressure gear lubricant
with an SAE rating per the ambient temperatures
shown below ‐ or until lubricant runs out of the oil
level hole. Always clean the drain plug thoroughly
before reinstalling it.
SAE RATING
TEMPERATURE RANGE
80
Below 40
_F/4 _C
90
From 40
_F/4 _C to 100 _F/38 _C
140
From 100
_F/38 _C to 150 _F/66 _C
After the initial change, change the lubricant after
every 500 hours of operation or every six months,
whichever comes first. Change the oil more fre
quently if the pump is operated continuously or in
stalled in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.