Installation - section b – Gorman-Rupp Pumps 03H1-GR 287634 and up User Manual
Page 8
0 SERIES
OM-01194
PAGE B - 1
INSTALLATION
INSTALLATION - SECTION B
Review all SAFETY information in Section A.
Since pump installations are seldom identical, this
section offers only general recommendations and
practices required to inspect, position, and ar
range the pump and piping.
Do not test or operate your pump and in
tegral gearbox before reading the in
stallation and operation instructions in
this manual.
This pump is a self‐priming centrifugal model with
an integral gearbox assembly. It is designed for ve
hicular mounting in petroleum service, where the
liquid is supplied to the pump under pressure.
Since the pressure supplied to the pump is critical
to performance and safety, be sure to limit the in
coming pressure to 50% of the maximum permissi
ble operating pressure as shown on the pump per
formance curve (see Section E, Page 1).
The integral gearbox is designed to be driven
through the vehicle transfer case by a customer‐
supplied universal shaft assembly. The pump cas
ing or gearbox may be rotated in 45
_ increments to
assist with alignment with the vehicle tank; howev
er, if the gearbox is to be rotated, some modifica
tions must be made to the gearbox to ensure ade
quate lubrication. Consult the factory for details.
For further assistance, contact your Gorman‐Rupp
distributor or the Gorman‐Rupp Company.
Pump Dimensions
See Figure 1 for the approximate physical dimen
sions of this pump.
OUTLINE DRAWING
Figure 1. Pump Model 03H1‐GR