background image

OM-06013

ULTRA V SERIES

MAINTENANCE & REPAIR

PAGE E - 16

If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.

To ease installation of the seal, lubricate the shaft

sleeve, shaft sleeve O‐ring and the external station­
ary seat O‐ring with a very small amount of light lu­
bricating oil. See Figure 8 for seal part identifica­
tion.

SEAL PLATE

O‐RINGS

IMPELLER

SHAFT

STATIONARY

SEAT

STATIONARY

ELEMENT

ROTATING

ELEMENT

DRIVE BAND

BELLOWS

IMPELLER

SHIMS

IMPELLER

SPRING

RETAINER

SEAL SLEEVE

O‐RING

INTEGRAL

SHAFT

SLEEVE

Figure 8. Cartridge Seal Assembly

This seal is not designed for operation at
temperatures above 160

_

F (71

_

C). Do not

use at higher operating temperatures.

If the seal plate was removed, install the seal plate
gasket (5). Position the seal plate over the shaft
and secure it to the bearing housing with the hard­
ware (7 and 8).

To prevent damaging the shaft sleeve O‐ring (27)
on the shaft threads, stretch the O‐ring over a piece
of plastic tubing that the I.D. is a little larger than the
O.D. of the shaft. Slide the tube over the shaft
threads, then slide the O‐ring off the tube and onto
the shaft. Remove the tube, and continue to slide

the O‐ring down the shaft until it seats against the
shaft shoulder.

When installing a new cartridge seal assembly,
remove the seal from the container, and remove
the mylar storage tabs, if so equipped, from be­
tween the seal faces.

Some cartridge seal assemblies are
equipped with mylar storage tabs between
the seal faces. These storage tabs must be
removed before installing the seal.

Lubricate the external stationary seat O‐ring with
light oil. Slide the seal assembly onto the shaft until