Gorman-Rupp Pumps UNIT 608 1347755 thru 1395613 User Manual
Page 9
OM−01228
UNIT SERIES
PAGE B − 2
INSTALLATION
Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.
UNIT INSTALLATION
Lifting
This unit is mounted on a two-wheel moveable
base. It weighs approximately 260 pounds (118 ki-
lograms) including suction and discharge hoses
and the standpipe. If it is necessary to lift the unit,
use lifting equipment with a capacity of 5 times the
weight of the unit to ensure safe lifting.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment.
Mounting
Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount-
ing is essential for proper operation.
The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra-
tion.
Specifications
See Table 1 for typical pump specifications.
Table 1. Pump Specifications
Pump
Model
Voltage
Phase
Horse-
power
Motor
RPM
Cycle
Suction
Coupler
Discharge
Coupler
02D3
115/230
1
1
3450
60 Hz
1−1/2"
1−1/2"
See Table 1 for typical pump specifications.
Table 2. Unit Specifications
Power
Cable
Reel
Assembly
Suction
Hose
Ground
Wire
Standpipe Length
(Min) − (Max)
50 Ft.
(15,2 M.)
1−1/2" x 15 Ft.
38,1 MM x 4,6 M
10 Ft.
(3,1 M.)
42 Ft.
(12,8 M.)
Discharge
Hose
1−1/2" x 15 Ft.
38,1 MM x 4,6 M
7.25 Ft. − 12 Ft.
2,2 M − 3,7 M
Positioning Unit and Setup
Figure 2 shows a typical installation of the tank-
leenor
t system.