beautypg.com

Pump Solutions Group Neptune Calibration Columns User Manual

Calibration columns, Purpose, Features

background image

Calibration Columns

BULLETIN CC-08

Calibration Columns

Purpose

Neptune Calibration Columns provide a
fast, easy and economical means of checking
the flow rate of your chemical metering pump.

The most accurate test of metering pump flow rate
is to measure the drawdown rate on the suction side
while leaving the discharge undisturbed in its normal
steady state operating condition. Pump flow rate
verification on a periodic basis or after maintenance
is important to system accuracy.

The Calibration Column can also be used to determine
if check valves are worn or dirty.

It is recommended to size the Calibration Column for a
minimum of 30 seconds with a scale that will produce
an easily readable differential within the test period.

Features

• Rugged PVC construction with slip on top

caps for top filling and easy cleaning

• Shielded glass models available for acids

and strong chemicals

• Calibration scales are protected from harsh

chemical by Mylar lamination

Specifications

FOR USE

SCALE

DIMENSIONS

MODEL

CAPACITY

WITH PUMPS

GRADUATION

NUMBER

UP TO

INCREMENTS

A

B

C

CC 100

100 ml.

3 gph

1 ml.

14"

1-5/8"

1/2" FNPT

CC 250

250 ml.

7 gph

2 ml.

15"

2-1/4"

1/2" FNPT

CC 500

500 ml.

16 gph

5 ml.

15-5/8"

2-3/4"

3/4" FNPT

CC 1000

1000 ml.

30 gph

5 ml.

26-3/8"

2-3/4"

3/4" FNPT

CC 4000

4000 ml.

120 gph

20 ml.

31-1/2"

5"

2" FNPT

B

A

C (INLET