8 Controller menu of the programming device
To reach the controller menu, you have to press Î on the controller for longer than 3 sec.,
when the
1
st
display
POWER X.X %
SPEED X.X Hz
The actual values are displayed.
is shown. Then the display will change to
Address 01
P1:run
The actual pump-address is shown
P1 ...Master
run ... HVS running
P2 ...Slave
disabled ... HVS is not ready / extern on /off
P. ... not active
stop ... HVS is ready, but not running
Error ... Error message or no supply voltage
Then press
Í
on the controller to change to
8.1 Controller menu Configuration
Submenu
Configuration
To enter this menu you have to press the Ð
button, to
leave the menu, press the Îbutton longer than 3 sec.
8.1.1 Automatic connection to the programming device
Auto Connecting
Enabled
! Only valid for programming device!
Auto connecting enabled: after plug in the programming device, it changes
automatically to the inverter menu. During this auto connection the programming
device is looking for a valid address and “SCAN CONNECTION” is shown on the
display.
Auto connecting disabled: there is no automatic connecting with the pump (choose
the address)
Auto connecting will be saved after leaving the submenu Configuration
8.1.2 Software Version
Software:
Software: VOGREM-XXX
In the second line of the display, there is shown the
version of the software of the programming device
and also the date of programming of this software.