Xylem HYDROQSG Hydrovar Quick Start Guide User Manual
Page 2

100
SUBMENU
BASIC SETTINGS
200
SUBMENU
C
ONF INVER
TER
300
SUBMENU
REGULA
TION
400
SUBMENU
SENSOR
500
SUBMENU
SEQUENCE CNTR
100
SUBMENU
BASIC SETTINGS
60
SUBMENU
SETTINGS
200
SUBMENU
C
ONF INVER
TER
300
SUBMENU
REGULA
TION
400
SUBMENU
SENSOR
500
SUBMENU
SEQUENCE CNTR
61
PASSW
ORD
0000
105
MODE
C
ontr
oller
202
SOFTW
ARE
HV
V01.3
205
MAX.
UNITS
6
210
INVER
TER
ALL
215
RAMP 1
4 sec
225
RAMP 3
70 sec
260
FMIN TIME
0 sec
265
BOOS
T
5 %
310
WINDOW
10 %
510
A
CT
.V
AL.DEC
2 PSI
540
DROP FREQ
42.0 Hz
410
C
ONF
SENSOR
Sensor 1
315
HYS
TERESIS
80 %
515
ENABLE FREQ
48 Hz
545
O
VER
VAL
UE
disabled
415
SENSOR T
YPE
analog I 4-20mA
320
REG.
MODE
normal
520
ENABLE DL
Y
5 sec
550
O
VER
VAL
DL
Y
0 sec
420
SENS.
RANGE
300 PSI
325
FRQ.
LIFT
30.0 Hz
525
SWIT
CH DL
Y
2 sec
555
SWIT
CH INTV
24 hours
425
SENS.
CUR
VE
line
ar
330
LIFT
AMOUNT
0.0 %
530
DISABLE
FRQ
30.0 Hz
560
S
YNCH.LIM.
0.0 Hz
565
S
YNCH.
WIN.
2 Hz
570
MS
TPRIORIT
Y
ON
430
SENS1 C
AL
0
0 % = x,xx PSI
440
SENS2 C
AL
0
0 % = x,xx PSI
435
SENS1
CAL
X
0 % = xx,xx PSI
445
SENS2
CAL
X
0 % = xx,xx PSI
285
SKIPFRQ C
TR
0.0 Hz
270
KNEE
FREQ.
60 Hz
286
SKIPFRQ
RNG
60 Hz
275
POWER RED
.
OFF
290
CURR.
LIMIT
OFF
280
SEL.SW
.FRQ.
Auto
291
CURR.
LIMIT
100 %
230
RAMP 4
70 sec
235
RAMP
FMIN
A
2 sec
240
RAMP FMIN D
2 sec
245
MAX.
FREQ
60 Hz
250
MIN.
FREQ
20 Hz
220
RAMP 2
4 sec
203
SET
VER
INV
sel.
01
act.
01
106
PUMP
ADDR
1
110
SET
P
ASSW
.
0066
115
LOCK
FUNC
T.
0066
120
DISP
. C
ONTR.
75 %
125
DISP
. BRIGHT
100 %
62
JOG
Hz
50 PSI
305
JOG
Hz
50 PSI
505
A
CT
.V
AL.INC
5 PSI
535
DISABLE DL
Y
5 sec
405
DIMENS.
UNIT
PSI
255
C
ONF
. FMIN
F > 0
1000
SUBMENU
TES
TRUN
800
SUBMENU
REQUIRED V
AL
UES
700
SUBMENU
OUTPUTS
1000
SUBMENU
TES
TRUN
1100
SUBMENU
SETUPS
1100
SUBMENU
SETUPS
605
MIN.
THRESH.
disabled
705
ANAL
OG OUT1
Output fr
equency
1005
TES
TRUN
100 hours
610
DELA
Y
TIME
2 sec
1010
TES
TRUN
FREQ.
30 Hz
710
ANAL
OG OUT2
Actual value
810
C.REQ.
V
AL.2
OFF
1120
P
ASSW
ORD 2
0000
907
OFFS.INPUT
100
1210
BA
UDRA
TE
9600
1215
FORMA
T
R
TU N81
830
A
C
TU
A
T.FRQ1
0.0 Hz
1220
PUMP ADDR
1
835
A
C
TU
A
T.FRQ2
0.0 Hz
805
C.REQ.
V
AL.1
digital
1110
F
A
C
TOR
Y SET
USA
905
OFFS.INPUT
OFF
1205
ADDRESS
1
615
ERROR RESET
ON
1015
TES
TR.BOOS
T
10 %
715
C
ONF REL
1
R
unning
815
SW
REQ.
V
AL
Setpoint 1
1125
CLR ERRORS
ALL
910
LEVEL
1
0
915
LEVEL
2
100
1020
TES
TR.
TIME
5 sec
720
C
ONF REL
2
Err
ors
820
REQ.
V
AL.1
50 PSI
1130
CLR
MO
TORH.
ALL
912
OFFSET
X1
0
917
OFFSET
X2
100
1025
SEL.DEVICE
01
1030
TES
TRUN MAN
Pr
ess > 3 sec
825
REQ.
V
AL.2
50 PSI
1135
CLR OPERA
T.
Pr
ess > 3 sec
913
OFFSET
Y1
0 PSI
918
OFFSET
Y2
0 PSI
800
SUBMENU
REQUIRED V
AL
UES
600
SUBMENU
ERRORS
600
SUBMENU
ERRORS
700
SUBMENU
OUTPUTS
1200
SUBMENU
RS485-INTERF
A
CE
1200
SUBMENU
RS485-INTERF
A
CE
900
SUBMENU
OFFSET
900
SUBMENU
OFFSET