INSTALLATION
18
12e
8
CONNECTION IN DUCTING VERSION
When installing the hood in ducting version, a rigid
or a flexible pipe with the diameter corresponding
to the flange diameter is used in order to connect
the hood to the air outlet piping.
• Fix the pipe with an adequate quantity of pipe
clamps (not supplied).
• Remove possible charcoal filters.
CONNECTION IN RECYCLING VERSION
• Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
• Insert the flange
10a on the hood body outlet.
• Connect the flange to the outlet on the shelf over
the hood using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Fix the directional grille
8 on the recirculation air
outlet using the 2 screws
12e (2,9 x 12,7) provid-
ed.
• Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm.