• Do not let the power cable to heat up

to a temperature higher than 90° C.

Make sure that you connect the blue
neutral cable to the terminal with a letter
"N" on it. Connect the brown (or black)
phase cable to the terminal which has a
letter "L". Keep the phase cable connec-
ted at all times.

8.3 Replacement of the
connection cable

To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.

8.4 Building In

min.

55 mm

min.

650 mm

560 mm

480 mm

min.

100 mm

30 mm

10 mm

3 mm

11 mm

11 mm

A

A

B

A)

supplied seal

B)

supplied brackets

CAUTION!
Install the appliance only on a
worktop with flat surface.

8.5 Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

B

A

A)

Removable panel

B)

Space for connections

20 www.aeg.com