8 enabling writecache – Asus Z8PH-D12 SE/QDR User Manual
Page 124
5-24
Chapter 5: RAID configuration
5.2.8
Enabling WriteCache
You may manually enable the RAID controller’s WriteCache option after creating a
RAID set to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs
while transmitting or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets.
To enable WriteCache
1.
From the
Management Menu, select Objects > Adapter, and then press
2.
Select
Disk WC, and then press
3.
When finished, press any key to continue.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Objects
Adapter
Virtual Drive
Physical Drive
Adapter 0
Rebuild Rate = 30
Chk Const Rate = 30
FGI Rate = 30
BGI Rate = 30
Disk WC = Off
Read Ahead = On
Bios State = Enable
Stop On Error = No
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
Disk Coercion = 1GB
Factory Default
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version A.08.09161344R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option