CONTROLS
Button Function
Led
L
Turns the lights on/off at maximum strength.
-
T1
Turns the motor on/off at speed one.
Fixed.
T2
Turns the Motor on at speed two.
Press and hold the button for approximately 3 seconds, with all the
loads turned off (Motor and Lights), to turn the Activated Charcoal
Filter alarm on. The relevant LED flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least
3 seconds. The relevant LED flashes once.
Fixed.
T3
Turns the Motor on at speed three.
Press and hold the button for approximately 3 seconds, with all the
loads turned off (Motor and Lights), to perform a reset. The LED
S1 flashes three times.
Fixed.
T4
Turns the Motor on at INTENSIVE Speed.
This speed is timed to run for 10 minutes. At the end of this time,
the system returns automatically to the speed that was set before.
If it is activated with the motor turned off, the hood will switch to
OFF at the end of the time.
Press and hold for 3 seconds to enable the remote control,
indicated by the LED flashing twice.
Press and hold for 3 seconds to disable the remote control,
indicated by the LED flashing just once.
Fixed.
S1
Signals the Metal Grease Filter saturation alarm, indicating that it
is necessary to wash the filters. The alarm is triggered after the
Hood has been in operation for 100 working hours. (Reset see the
parag. Maintenance).
Fixed.
When this is activated, it signals the Activated Charcoal Filter
saturation alarm, indicating that the filter must be changed; the
Metal Grease Filters must also be washed. The Activated Charcoal
Filter saturation alarm comes into operation after the Hood has
been working for 200 hours. (Activation and Reset see the parag.
Maintenance)
Flashing.