6-1
NOTES:
1)
Replenishment of pH adjusting component of media may be required periodically, the frequency of which is dependent on raw water pH, manga-
nese concentration and water consumption rate. Consult Customer Service Department at 1-866-990-9785 for more information.
2)
For satisfactory performance, indicated durations should not be exceeded. Flow rates specifi ed are adequate for normal residential applications.
Do not use Service or Peak fl ow rates when sizing applications if treated water is to supply a geothermal heat pump, swimming pool, etc. (contact
Customer Service Department at 1-866-990-9785 before selecting equipment).
3)
For system to operate properly, pumping rate of well pump MUST be suffi cient to backwash unit at rate specifi ed.
Maximum Operating Temperature 110°F (43.3°C)
Electrical requirements 110V/60Hz
Operating Pressure 20-50 psi.
Specifi cations subject to change without notice.
ITEM
APPM100
APPM100M
APPM100DM
APPM100MDM
APPM150
APPM150M
APPM150DM
APPM150MDM
APPM200
APPM200M
APPM200DM
APPM200MDM
Filter Media Volume, (Note 1) Cu ft. (Cu meters)
1.0 (0.02)
1.5 (0.04)
2 (0.06)
Gravel Underbed, Lbs. (kg)
13 (5.9)
13 (5.9)
18 (8.2)
Nominal Capacity, (ppm-gal)
45,000
45,000
60,000
Flow Rate gpm, (Note 2)
Service – gpm (lpm)
Backwash – gpm (lpm)
5 (19)
5.3 (20)
7 (26.5)
5.3 (20)
9 (34)
7.5 (28.4)
Pressure Loss at Service Flow Rate – psi (kPa)
5 (34.47)
5 (34.47)
6 (41.37)
Service Pipe Size, Inches (NPT)
1
1
1
Aeration Tank Diameter x Height, Inch (cm)
10 x 54
(26 x 137)
10 x 54
(26 x 137)
10 x 54
(26 x 137)
Media tank Diameter x Height, Inch (cm)
10 x 54
(26 x 137)
10 x 54
(26 x 137)
12 x 54
(31 x 137)
Minimum Space Required,
Width Inch (cm)
Depth w/Bypass Inch (cm)
Height Inch (cm)
30 (72.6)
16 (41)
63 (160)
30 (72.6)
16 (41)
63 (160)
32 (81.3)
16 (41)
63 (160)
Approximate Ship Weight; Lbs. (kg)
186 (84.4)
186 (84.4)
257 (116.6)
Section 6: SPECIFICATION & OPERATING DATA