8.6 Building In

min. 55 mm

min. 650 mm

560 mm

min. 100 mm

30 mm

480 mm

600 mm

10 mm

86 mm

86 mm

A

3 mm

A

B

A)

supplied seal

B)

supplied brackets

CAUTION!
Install the appliance only on a
worktop with flat surface.

8.7 Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

B

A

A)

Removable panel

B)

Space for connections

Kitchen unit with oven

The hob recess dimensions must obey
the indication and the kitchen unit must
be equipped with vents to let a continu-
ous supply of air. The electrical connec-
tion of the hob and the oven must be in-
stalled separately for safety reasons and
to let easy remove oven from the unit.

50 cm

2

360 cm

2

180 cm

2

120 cm

2