CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price
Pfister Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
12 VALVE FUNCTION
COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise.
Note: Flush faucet before turning on valve (see step 13).
13 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (13A). Turn Valves (13B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (13A) by
separating the Aerator Shell (13C), Basket (13D) and Washer (13E). Once parts have
been cleaned, reassemble by reversing steps.
14 HANDLE INSTALLATION REMOVAL
Turn off water before proceeding! With Valves in “Closed” position, unscrew Fastener
(14A) and remove Handle Hub (14B) from Valve Stem (14C).
15 VALVE CARTRIDGE MAINTENANCE
Turn off water supplies and relieve pressure before working on your faucet.
Remove handle (refer to step 14). Loosen the retainer nut (15A) by turning it counter-
clockwise and lift out the cartridge assembly (15B). Replace parts as necessary. Re-
insert the cartridge into the faucet body. Make sure the wings (15C) on the two sides
of the cartridge bonnet fit well into the slots (15D) on the faucet body. Tightly screw the
retainer nut (15A) by turning it clockwise. Reinstall the handle.