12
DESCRIPTION OF CONTROLS
Credit for coins or tokens inserted, dryer time, and temperature are controlled by an electronic controller.
The large digital display shows vend price of an idle dryer, time purchased after coins or tokens are deposited,
temperature, and program information.
The three red indicator lights show the drying temperature selected. This selection may be made anytime.
The drying temperature will be displayed when the "Start" button and the temperature button for the
selected temperature are pressed at the same time.
All programmed data is protected from power interruption of any length and the customer’s individual cycle is
protected for up to 3 seconds. This is done without batteries.
The 3 temperature buttons and the "Start" button become programming switches when the controller is in
the program mode as described on page 13.
PROGRAMMING:
All operating parameters (vend price, temperatures, cool-down times, etc.) are adjustable. In addition, several
displays of information are available from the controller (Money audits, hours run, dryer temperature).
The dryer is ready to run, from the factory, with the following pre-programmed data:
Temperature, HIGH :
175°F / 78°C
Temperature, MEDIUM :
150°F / 63°C
Temperature, LOW :
125°F / 48°C
Vend Price:
25¢
Time for Left Coin:
3:20 (doesn't apply to single coin models)
Time for Right Coin:
8:00 (8 minutes for 25¢)
Time of Free Vend:
8:00 (“Free Dry” cycle is 8 minutes)
Cool-down Time, HIGH :
2:00 (Cool-down time in HIGH is 2 minutes)
Cool-down Time, MEDIUM :
2:00 (Same as above, except MEDIUM)
Cool-down Time, LOW :
2:00 (Same as above, except LOW)
Temperature Scale
F degrees
Decimal Point Display
ON
Seconds on Display
OFF
All of the above data can be easily changed by the owner. The changes are made by the 4 keys or buttons on
the front of the control panel.