Neutrik NBNB75GUU11 User Manual
Assembly instruction, 75 cable jack panel version
Slide the crimp ferrule onto the cable
Spread the braided shield
- position the pin on the center conductor
- Crimp the pin with the tool
- Pin can also be soldered (Optional)!
- Straighten the pin if misaligned.
crimp
and push the cable and leading ferrule to it`s end
position until you hear a snap noise.
Crimp the ferrule with the tool
(It`s easily with the Neutrik
“SHIELD-SPREADING-TOOL”!)
(For best crimping-results it is recommended to use the original
Neutrik tool - HXBNC with the corresponding insert)
(For best crimping-results it is recommended to use the
original Neutrik crimp tool
- HXBNC with the corresponding insert
or hexcrimp acc. to IEC 803-W (SW 1.7)
or squarecrimp acc. to IEC 803-2 (SW 1.6)
Prepare cable as shown
- Use an adjustable coaxial cable stripper
Crimp the pin
Insert the cable into the connector body
Slide the
ferrule over the shield to the front
Please note:
Position the connector body
flush with the die face.
A
A
B
C
D
D
E
F
G
B
C
CRIMP
OPERATION!
Don't damage the foil!
(if existing)
Pin flush to the insulator
G
C: 4 [.16”]
B: 9 [.354”]
A: 16 [.630”]
Crimp ferrule
X
Labeling
X
E
F
X
BNC
75
Cable Jack Panel version
|
W
ASSEMBLY INSTRUCTION
Draft. Nr.: BDA 120
Update:
09.04.2008
/ 3102M1201
I
I
Data subject to change without prior notice.
2008NEUTRIK . ALL RIGHTS RESERVED.
©
®
www.neutrik.com
NEUTRIK AG
NEUTRIK Zürich AG
NEUTRIK USA Inc.
NEUTRIK UK Ltd.
(
)
LI
CH
USA
UK
T:
F:
T:
F:
T:
F:
T:
F:
+423 / 237 24 24
+423 / 232 53 93
+41 44 / 736 5010
+41 44 / 736 5011
+1 732 / 901 9488
+1 732 / 901 9608
+44 1983 / 811 441
+44 1983 / 811 439
NEUTRIK
NEUTRIK France
NEUTRIK Tokyo Ltd.
NEUTRIK
Vertriebs GmbH
Ltd.
Hong Kong
DE / NL / AT
FR
JP
HK
T:
F:
T:
F:
T:
F:
T:
F:
+49 8131 / 280 890
+49 8131 / 280 830
+33 1 / 4131 6750
+33 1 / 4131 0511
+81 3 / 3663 4733
+81 3 / 3663 4796
+852 / 2687 6055
+852 / 2687 6052