1 Function generator FG100 (115 V, 50/60 Hz)
1009956
or
1 Function generator FG100 (230 V, 50/60 Hz)
1009957
•
Set up the experiment as in fig. 4.
•
Place the auxiliary coil on the upper fork of
the tube holder. Push the jaw clamp over the
lip of the coil to secure it in place.
•
Connect the auxiliary coil to the alternating
current source.
•
Connect the Helmholtz coils to the function
generator and choose a sinusoidal signal.
•
Apply a voltage to the anode between 3 kV
and 5 kV.
•
Apply an alternating voltage up to 15 V to
the auxiliary coil and observe the horizontal
deflection.
•
Set a frequency of e.g. 50 Hz at the function
generator, vary the amplitude of the sine-
signal and observe the Lissajous figures on
the fluorescent screen.
DC POWER SUPPLY 0 ... 5 kV
0
1
2
3
4
5
KV
0 ... 5 kV
Z
A
U
F
U
A
0
1
2
3
4
5
6
Z
A
-
Fig. 1 Evidence of the particle nature of cathode beam and establishment of their polarity
r
Fig. 2 Definition of the curvature radius r
- Piezoelectric Charge Source (2 pages)
- Animal cell model (36 pages)
- Internal organs Chart (16 pages)
- Digital Input Box (12 pages)
- Digital Input Box (2 pages)
- Experiment Set - On the Trail of Flavour Enhancers Brand new and topical-versatile in classroom situations (48 pages)
- Pascal’s Pressure Sphere (6 pages)
- Pascal’s Pressure Sphere (1 page)
- Heat Equivalent Apparatus (6 pages)
- Heat Equivalent Apparatus (24 pages)
- 3B Deluxe Portable Massage Table - Blue (2 pages)
- Radiation of Heat__Thermopile (12 pages)
- Radiation of Heat__Thermopile (2 pages)
- Capillary Tubes Apparatus (2 pages)
- Basic Experiment Board (230 V, 50__60 Hz) (24 pages)
- Model of female breast (30 pages)
- Digital Teslameter with Probe (230 V, 50__60 Hz) (4 pages)
- Brain with Arteries on Base of Head, 8 part (20 pages)
- Functional Physiological Skeleton Model - Frank - Hanging Stand (1 page)
- Physiological Skeleton Model - Phil - Hanging Stand (20 pages)
- Teltron Optical Equivalent to Debye-Scherrer Interference (2 pages)
- Teltron Luminescence Tube D (4 pages)
- Teltron Triode D, Helium-filled (4 pages)
- Human Blood Circulation Chart (16 pages)
- Power Function Generator (230 V, 50__60 Hz) (4 pages)
- Power Function Generator (115 V, 50__60 Hz) (24 pages)
- Laser Diode for Debye-Sears Effect, Red (5 pages)
- Lung Model with larynx, 7 part (16 pages)
- The Human Skeleton Chart, front (16 pages)
- Solar Energy Basic Kit (2 pages)
- Solar Energy Basic Kit (12 pages)
- 1002996 (2 pages)
- 1000731 (1 page)
- Basic Mechanics Kit (2 pages)
- Teltron Dual Beam Tube S (6 pages)
- Resusci Anne CPR Torso (73 pages)
- Leclanche Cell (2 pages)
- Human Pulse Sensor Box (24 pages)
- Human Pulse Sensor Box (4 pages)
- Advanced Thermodynamics Kit (3 pages)
- 1008528 (1 page)
- Life size Muscle Torso, 27 part (60 pages)
- Launcher S (12 pages)
- Launcher S (2 pages)
- Torso Chart (16 pages)