3B Scientific Teltron Helmholtz Coils D User Manual
3b scientific® physics
3B SCIENTIFIC® PHYSICS
1
Helmholtz Pair of Coils D 1000644
Instruction sheet
07/12 ALF
1 Coil
2 4-mm-sockets
3 Stand rod
4 Securing sleeves
1. Description
The Helmholtz coils are used to create magnetic
fields for deflecting electron beams and are at-
tached to the tube holder D (1008507). The tube
holder allows the coils to be set up in Helmholtz
configuration to generate a highly uniform mag-
netic field perpendicular to the axis of the tube.
The two air-filled coils are made of lacquered
copper wire on a plastic bobbin on an insulating
stand rod with plastic sleeves for insertion into
specially drilled holes on the demonstration tube
holder. Connections are labelled from the start
(A) to the end (Z) of the coil winding.
2. Technical data
Number of winding
turns: 320
each
Coil diameter:
136 mm approx.
Rod:
145 mm x 8 mm Ø
Max. current:
continuous: 1.0
A
momentary:
1.5 A (max. 10 min)
2.0 A (max. 3 min)
Effective impedance:
6
Ω approx.
Connectors: 4-mm
socket
Magnetic flux B in
Helmholtz-configuration: B = k * I, where
k = appr. 4,2 mT/A