3B Scientific Motor, 12 V DC User Manual
Page 2
![background image](/manuals/289013/2/background.png)
2
3. Technical data
Nominal voltage:
12 V DC
Max. permissible operating voltage:
15 V DC
Idling speed:
3800 rpm
Nominal speed at rated torque: 3100 rpm/5 mNm
Nominal current without load/
with nominal load:
55 / 210 mA
Power consumption:
2.9 W
Voltage per speed of rotation:
3.6 … 4.4
rpm
mV
Rotor impedance:
12
Ω
Starting torque:
29 mNm
Acceleration time (no-load):
12.5 ms
Direction of rotation:
Reversible
Max. permissible bearing load:
radial at shaft-end:
5.0 N
axial:
0.5 N
∗
In the case of older motor models from an earlier
range, the voltage sensitivity is in the range of:
2.8 … 3.6
rpm
mV
4. Sample experiments
Fig. 1: Experiments on uniform motion (top) and friction (bottom)
Fig. 2: Excitation of transverse waves in a rubber band using a sine wave generator
- Piezoelectric Charge Source (2 pages)
- Animal cell model (36 pages)
- Internal organs Chart (16 pages)
- Digital Input Box (2 pages)
- Digital Input Box (12 pages)
- Experiment Set - On the Trail of Flavour Enhancers Brand new and topical-versatile in classroom situations (48 pages)
- Pascal’s Pressure Sphere (6 pages)
- Pascal’s Pressure Sphere (1 page)
- Heat Equivalent Apparatus (6 pages)
- Heat Equivalent Apparatus (24 pages)
- 3B Deluxe Portable Massage Table - Blue (2 pages)
- Radiation of Heat__Thermopile (2 pages)
- Radiation of Heat__Thermopile (12 pages)
- Capillary Tubes Apparatus (2 pages)
- Basic Experiment Board (230 V, 50__60 Hz) (24 pages)
- Model of female breast (30 pages)
- Digital Teslameter with Probe (230 V, 50__60 Hz) (4 pages)
- Brain with Arteries on Base of Head, 8 part (20 pages)
- Functional Physiological Skeleton Model - Frank - Hanging Stand (1 page)
- Physiological Skeleton Model - Phil - Hanging Stand (20 pages)
- Teltron Optical Equivalent to Debye-Scherrer Interference (2 pages)
- Teltron Luminescence Tube D (4 pages)
- Teltron Triode D, Helium-filled (4 pages)
- Human Blood Circulation Chart (16 pages)
- Power Function Generator (230 V, 50__60 Hz) (4 pages)
- Power Function Generator (115 V, 50__60 Hz) (24 pages)
- Laser Diode for Debye-Sears Effect, Red (5 pages)
- Lung Model with larynx, 7 part (16 pages)
- The Human Skeleton Chart, front (16 pages)
- Solar Energy Basic Kit (12 pages)
- Solar Energy Basic Kit (2 pages)
- 1002996 (2 pages)
- 1000731 (1 page)
- Basic Mechanics Kit (2 pages)
- Teltron Dual Beam Tube S (6 pages)
- Resusci Anne CPR Torso (73 pages)
- Leclanche Cell (2 pages)
- Human Pulse Sensor Box (24 pages)
- Human Pulse Sensor Box (4 pages)
- Advanced Thermodynamics Kit (3 pages)
- 1008528 (1 page)
- Life size Muscle Torso, 27 part (60 pages)
- Launcher S (2 pages)
- Launcher S (12 pages)
- Torso Chart (16 pages)