beautypg.com

3B Scientific Electroscope User Manual

Page 2

background image

4

with the earth socket on the power supply and
with the earth socket on the electroscope.

Use a charge spoon (e.g. U11051) to draw a charge
from the capacitor plate and transfer it to the elec-
troscope.

3.2 Using electrostatic induction to charge up the

electroscope

Approach but do not touch the sphere (or capaci-
tor plate) with the statically charged friction rod.

The pointer deflects.

Remove the friction rod. The pointer returns to
normal.

Again approach the sphere with the statically
charged friction rod. Once again the pointer deflects.

Briefly touch the sphere with your finger to dis-
charge it. The pointer deflection disappears and
returns to normal.

Now remove the friction rod. The pointer again
shows deflection.

Fig. 1:

Charging the electroscope using the high-voltage
power supply U21060

Fig. 2:

Charging the electroscope using a statically-charged
friction rod

3B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany • www.3bscientific.com • Technical amendments are possible