10GBASE-LR SFP+ SMF
1310NM 10KM REACH LC
Receiver power (damage, Max)
1.5
dBm
Note:
1. Average optical power shall be measured using the methods specified in
TIA/EIA-455-95.
2. Receiver sensitivity is informative. Stressed receiver sensitivity shall be
measured with conformance test signal for BER =1x 10
-12
3. Vertical eye closure penalty and stressed eye jitter are the test conditions for
measuring stressed receiver sensitivity. They are not the required characteristic
of the receiver.
4. Power budget is defined as the different between the Rx sensitivity and the Tx.
Output power of the interface.
5. Path penalty is intended as the power penalty of the interface between back-to-
back and the maximum applied dispersion.
8. DIGITAL DIAGNOSTIC FUNCTIONS
The following digital diagnostic characteristics are defined over the Recommended
Operating Environment unless otherwise specified. It is compliant to SFF8472
Rev10.2 with internal calibration mode. For external calibration please contact our
sales staff.
Parameters
Symbol
Min.
Max.
Unit
Notes
Temperature monitor
absolute error
DMI_Temp
-3
3
degC
Over operating temp
Laser power monitor
absolute error
DMI_TX
-3
3
dB
RX power monitor
absolute error
DMI_RX
-3
3
dB
-1dBm to -15dBm
range
Supply voltage
monitor absolute error
DMI_VCC
-0.08
0.08
V
Full operating range
Bias current monitor
DMI_Ibias
-10%
10%
mA
Table 5: Digital diagnostic specification table