Fg-tran-xfpsr-a, Recommended operating conditions, High speed line characteristics – Approved Optics Approved FORTINET FG-TRAN-XFPSR User Manual
Page 3: High speed line output-dc characteristics, High speed line output-ac characteristics
Approved Optics
www.ApprovedOptics.com
Page 3 of 7
FG-TRAN-XFPSR-A
XFP, 10GBASE-SR 10G Ethernet Module
850nm, 300m, MMF, LC RoHS6
Recommended Operating Conditions
Parameter
Conditions
Symbol
Min.
Typical
Max.
Units
Operating Case
Temperature Range
0
+70
°C
Transceiver total
Power Consumption
P
1.5
2.3
W
Power Supply Voltage
@ 5.0V
V
4.75
5.00
5.25
V
Power Supply Voltage
@ 3.3V
V
3.135
3.300
3.465
V
Supply Current
@ V
CC
5
I
VCC
5
50
100
mA
Supply Current
@ V
CC
3
I
VCC
3
325
500
mA
High Speed Line Characteristics
Parameter
Conditions
Symbol
Min
Ty
Max
Units
Baud Rate nomina
9.95
10.7
Gbd
Baud Rate Tolerance
-100
+100
ppm
High Speed Line Output-DC Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Single Ended Output Impedance
Z
SE
40
50
60
Ω
Differential Output Impedance
Z
OD
80
100
120
Ω
High Speed Line Output-AC Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Differential Output Amplitude
V
OSPP
340
850
mV
Output Common Mode
V
CM
0
3.6
V
Transition Time Low to High
t
r
24
ps
Transition Time High to Low
t
f
24
ps
Differential Output Return
Loss
0.05—0.1GHz
0.1—5.5GHz
5.5—12GHz
20
8
(See1)
dB
Common Mode Output
Return Loss
2
)
0.1—15GHz
SCC 22
3
dB
Total Peak-to-peak Jitter
D
j
0.34
UI