beautypg.com

Digital diagnostic functions – Approved Optics Approved HP J9151A User Manual

Page 7

background image

Approved Optics, Inc.

www.ApprovedOptics.com

Page 7 of 9

 

 

J9151A-A
10GBASE-LR SFP+ SMF
1310NM 10KM REACH LC

 

 

 

 

 

 

Receiver power (damage, Max)

1.5

dBm

 

 

Note:

1. Average optical power shall be measured using the methods specified in

TIA/EIA-455-95.

2. Receiver sensitivity is informative. Stressed receiver sensitivity shall be

measured with conformance test signal for BER =1x 10

-12

3. Vertical eye closure penalty and stressed eye jitter are the test conditions for

measuring stressed receiver sensitivity. They are not the required characteristic
of the receiver.

4. Power budget is defined as the different between the Rx sensitivity and the Tx.

Output power of the interface.

5. Path penalty is intended as the power penalty of the interface between back-to-

back and the maximum applied dispersion.

 

8. DIGITAL DIAGNOSTIC FUNCTIONS

 

The following digital diagnostic characteristics are defined over the Recommended
Operating Environment unless otherwise specified. It is compliant to SFF8472
Rev10.2 with internal calibration mode. For external calibration please contact our
sales staff.

 

Parameters

Symbol

Min.

Max.

Unit

Notes

Temperature monitor
absolute error

 

DMI_Temp

-3

3

degC

Over operating temp

Laser power monitor
absolute error

 

DMI_TX

-3

3

dB

 

RX power monitor
absolute error

 

DMI_RX

-3

3

dB

-1dBm to -15dBm

range

Supply voltage
monitor absolute error

 

DMI_VCC

-0.08

0.08

V

Full operating range

 

Bias current monitor

DMI_Ibias

-10%

10%

mA

 

 

Table 5: Digital diagnostic specification table