Absolute maximum ratings, Recommended operating conditions, Electrical characteristics – Approved Optics Approved EXTREME 10122 User Manual
Page 2
10122-A
XFP, 10GBASE-LR 10G Ethernet Module
1310nm, 10km, SMF, LC RoHS6
_______________________________________________________
Approved Optics, Inc. www.ApprovedOptics.com
Page 2 of 5
Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Unit
Maximum Supply Voltage 1
VCC3
-0.5
4.0
V
Maximum Supply Voltage 2
VCC5
-0.5
6.0
V
Storage Temperature
Ts
-40
85
°C
Case Operating Temperature
Top
-5
70
°C
Recommended Operating Conditions
Parameter
Symbol
Min.
Typical
Max.
Unit
Operating Temperature
Top
-5
70
°C
Supply Voltage 1
VCC3
3.13
3.45
V
Supply Voltage 2
VCC5
4.75
5.25
V
Electrical Characteristics
(TOP = -5 to 70°C, VCC5 = 4.75 to 5.25 Volts)
Parameter
Symbol
Min
Typ
Max
Unit
Note
Main Supply Voltage
Vcc5
4.75
5.25
V
Supply Voltage S#2
Vcc3
3.13
3.45
V
Supply Current
Vcc5
Icc5
250
mA
Supply Current
Vcc3
Icc3
500
mA
Module total power
P
2.5
W
Transmitter
Input differential impedance
Rin
100
Ω
1
Differential data input swing
Vin,pp
120
820
mV
Transmit Disable Voltage
VD
2
Vcc
V
Transmit Enable Voltage
VEN
GND
GND+0.8
V
Transmit Disable Assert
Time
10
us
Receiver
Differential data output swing
Vout,pp
340
650
850
mV
Data output rise time
tr
38
ps
2
Data output fall time
tf
38
ps
2
LOS Fault
VLOS fault
Vcc–
0.5
VccHOST
V
3