MODEL
PowerWalker
VI 400
PowerWalker
VI 600
PowerWalker
VI 800
CAPACITY
VA/W
400VA/240W
600VA/360W
800VA/480W
Voltage
110/120VAC or 220/230/240VAC
Voltage Range
85-140VAC or 162-290VAC
INPUT
Frequency
45-65 Hz (Auto Sensing)
Voltage (Batt. Mode)
110/120/220/230/240VAC +/-10%
Frequency (Batt. Mode)
50Hz or 60Hz +/-1 Hz
OUTPUT
Output Waveform
(line mode)Battery mode
Modified Sinewave Stepwave
Battery Type
12V4.5Ah x 1
12V7Ah x 1
12V9Ah x 1
Backup Time (at a PC
load with 15" monitor)
8 minutes
20 minutes
30 minutes
BATTERY
Recharge Time
8 hours to 90% after complete discharge
TRANSFER
TIME
Typical : 4-6 ms and 13ms(max)
AC Mode
Green lighting
INDICATOR
Backup Mode
Green flashing
Backup Mode
Sounding every 10 seconds
Low Battery
Sounding every second
AUDIBLE
ALARM
Overload
Sounding every 0.5 second
PROTECTION Full Protection
Discharge, overcharge, and overload protection
PHYSICAL
Dimension DxWxH(mm)
287x212x107
ENVIRONMENT Noise Level
Less than 40dB
Smart RS-232
Windows family, Sun Solaris, IBM Aix, Compaq
True64, UnixWare, FreeBSD, HP-UX, Linux and
MAC
INTERFACE
5. MONITORING SOFTWARE
After the UPS has been installed, you must install the
software(Smart Power) that came packaged with your
UPS. Smart Power monitoring software performs the
monitoring and controlling functions. This software
displays the status and diagnostic symptoms on the
monitor. In case of the power failure, it provides the auto
shutdown for the computer.
If you download the software from Internet, please key
the serial number: 726T25-4791-2N39546.