beautypg.com

Electrical characteristics, Note 1), Note 2) – Rainbow Electronics LM70 User Manual

Page 6: Note 3), Note 4), Note 5), Note 6), Note 7), Note 8), Note 9)

background image

Electrical Characteristics

Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating
the device beyond its rated operating conditions.

Note 2: When the input voltage (V

I

) at any pin exceeds the power supplies (V

I

<

GND or V

I

>

+V

S

) the current at that pin should be limited to 5 mA. The 20 mA

maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 5 mA to four.

Note 3: See the section titled “Surface Mount” found in a current National Semiconductor Linear Data Book for other methods of soldering surface mount devices.

Note 4: Human body model, 100 pF discharged through a 1.5 k

Ω resistor. Machine model, 200 pF discharged directly into each pin.

Note 5: The life expectancy of the LM70 will be reduced when operating at elevated temperatures. LM70

θ

JA

(thermal resistance, junction-to-ambient) when

attached to a printed circuit board with 2 oz. foil is summarized in the table below:

Device Number

NS Package

Number

Thermal

Resistance (

θ

JA

)

LM70CILD

LDA08A

51.3˚C/W

LM70CIMM

MUA08A

200˚C/W

Note 6: Both part numbers of the LM70 will operate properly over the V

+

supply voltage range of 2.65V to 5.5V. The temperature error for temperature ranges of

−10˚C to +65˚C, −40˚C to +85˚C, −55˚C to +125˚C and −55˚C to +150˚C include error induced by power supply variation of

±

5% from the nominal value.

Temperature error will increase by

±

0.3˚C for a power supply voltage (V

+

) variation of

±

10% from the nominal value.

Note 7: Typicals are at T

A

= 25˚C and represent most likely parametric norm.

Note 8: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).

Note 9: This specification is provided only to indicate how often temperature data is updated. The LM70 can be read at any time without regard to conversion state
(and will yield last conversion result). A conversion in progress will not be interrupted. The output shift register will be updated at the completion of the read and a
new conversion restarted.

Note 10: For best accuracy, minimize output loading. Higher sink currents can affect sensor accuracy with internal heating. This can cause an error of 0.64˚C at full
rated sink current and saturation voltage based on junction-to-ambient thermal resistance.

LM70

www.national.com

6