DS2710

Single-Cell NiMH Charger

6

_______________________________________________________________________________________

PRECHARGE

CS = ACTIVE 25% DF

STATUS = 1Hz TOGGLE

CELL TEST

CS = INACTIVE

STATUS = HIGH

FAST-CHARGE

CS = ACTIVE

STATUS = HIGH

TOP-OFF

CS = ACTIVE 25% DF

STATUS = HIGH

MAINTENANCE

CS = ACTIVE 1.56% DF

STATUS = LOW

FAULT

CS = INACTIVE

STATUS = 4Hz TOGGLE

PRESENCE

CS = INACTIVE

STATUS = LOW

t < FAST TIMEOUT

t < TOP-OFF TIMEOUT

t > FAST TIMEOUT

T > +50

°C

PASS

31s INTERVAL

SUSPEND

CS = INACTIVE

STATUS = LOW

R

TMR

> R

SUSPEND

(ASYNCHRONOUSLY FROM ANYWHERE)

R

TMR

< R

SUSPEND

V

DD

> V

UVLO

(3.5V)

V

DD

< V

UVLO

- V

UHYS

(ASYNCHRONOUSLY FROM ANYWHERE)

t < t

PCHG

AND

V

CELL

< 1.0V

V

CELL

> 1.0V

AND

t < t

PCHG

AND

T < +50

°C

t > t

PCHG

OR

T > +50

°C

OR

V

CELL

> V

MAX

*

T > +50

°C

OR

t > TOP-OFF TIMEOUT

-

ΔV DETECT

OR

FLAT VOLTAGE DETECT

*V

MAX

REPRESENTS V

MAX-CHARGE

WHEN THE CS OUTPUT IS ACTIVE AND V

MAX-OPEN

WHEN THE CS OUTPUT IS INACTIVE.

V

CELL

> 1.75V

OR
T < 0

°C

OR
T > +45

°C

V

CELL

> 1.75V

V

CELL

< V

MAX-OPEN

FAIL: V

CELL

> V

MAX-OPEN

OR

ΔV > CTEST

V

CELL

> V

MAX

*

V

CELL

> V

MAX

*

POR

CS = INACTIVE

Figure 2. State Diagram