background image

MAX5886

3.3V, 12-Bit, 500Msps High Dynamic

Performance DAC with Differential LVDS Inputs

_______________________________________________________________________________________

9

ended output voltages. The differential voltage existing
between IOUTP and IOUTN can also be converted to a
single-ended voltage using a transformer or a differen-
tial amplifier configuration. If no transformer is used, the
output should have a 50

Ω termination to the analog

ground and a 50

Ω resistor between the outputs.

Although not recommended because of additional
noise pickup from the ground plane, for single-ended
operation IOUTP should be selected as the output, with
IOUTN connected to AGND. Note that a single-ended
output configuration has a higher 2nd-order harmonic
distortion at high output frequencies than a differential
output configuration.

1.2V

REFERENCE

CURRENT-STEERING

DAC

FUNCTION

SELECTION

BLOCK

AGND

SEL0

DGND

DV

DD

REFIO

FSADJ

CLKN

CLKP

PD

AV

DD

IOUTP

IOUTN

SEGMENT SHUFFLING/LATCH

DECODER

LVDS RECEIVER/INPUT LATCH

12

DIFFERENTIAL DIGITAL INPUTS B0 THROUGH B11

MAX5886

Figure 1. Simplified MAX5886 Block Diagram

R

SET

(k

)

FULL-SCALE CURRENT

I

OUT

(mA)

REFERENCE CURRENT

I

REF

(µA)

CALCULATED

1% EIA STD

OUTPUT VOLTAGE

V

IOUTP/N

* (mV

P-P

)

2

62.5

19.2

19.1

100

5

156.25

7.68

7.5

250

10

312.5

3.84

3.83

500

15

468.75

2.56

2.55

750

20

625

1.92

1.91

1000

Table 1. I

OUT

and R

SET

Selection Matrix Based on a Typical 1.200V Reference Voltage