Max6338 quad voltage monitor in µmax package, Typical operating characteristics – Rainbow Electronics MAX6338 User Manual
Page 3

MAX6338
Quad Voltage Monitor in µMAX Package
_______________________________________________________________________________________
3
10
20
15
30
25
40
35
45
2.5
3.5
4.0
3.0
4.5
5.0
5.5
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX6338-01
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (
µ
A)
T
A
= +85
°C
T
A
= +25
°C
T
A
= -40
°C
-0.06
-0.04
-0.02
0
0.02
0.04
0.06
0.08
0.10
2.5
3.5
3.0
4.0
4.5
5.0
5.5
NORMALIZED THRESHOLD ERROR
vs. SUPPLY VOLTAGE
MAX6338-02
SUPPLY VOLTAGE (V)
NORMALIZED THRESHOLD ERROR (%)
NORMALIZED TO +5V
-0.3
-0.2
-0.1
0
0.1
-40
20
40
-20
0
60
80
NORMALIZE THRESHOLD
vs. TEMPERATURE
MAX6338-03
TEMPERATURE (
°C)
NORMALIZED THRESHOLD (%)
V
CC
= +5V
0
0.3
0.2
0.1
0.4
0.5
0.6
0
4
3
1
2
5
6
7
8
9
10
OUTPUT VOLTAGE LOW
vs. SINK CURRENT
MAX6338-04
SINK CURRENT (mA)
OUTPUT VOLTAGE LOW (V)
T
A
= +25
°C
V
CC
= 5V
T
A
= -40
°C
T
A
= +85
°C
PROPAGATION DELAY
(WITH 100mV OVERDRIVE)
MAX6338-05
10µs/div
IN_
50mV/div
OUT_
2V/div
PROPAGATION DELAY
(WITH 20mV OVERDRIVE)
MAX6338-06
10
µs/div
IN_
20mV/div
OUT_
2V/div
Typical Operating Characteristics
(V
CC
= +5V, T
A
= +25
°C, unless otherwise noted.)