beautypg.com

Rainbow Electronics MAX6608 User Manual

Page 2

background image

MAX6607/MAX6608

Low-Voltage Analog Temperature Sensors
in SC70 and SOT23 Packages

2

_______________________________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

ELECTRICAL CHARACTERISTICS

(V

CC

= +1.8V to +3.6V, C

L

= 1nF, T

A

= -20

°C to +85°C, typical values are at T

A

= +25

°C, unless otherwise noted.) (Note 1)

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

Note 1: All parameters are measured at T

A

= +25

°C. Specifications over temperature range are guaranteed by design.

Note 2: Not production tested, guaranteed by design.

V

CC

to GND ..............................................................-0.3V to +6V

OUT, A to GND...........................................-0.3V to (V

CC

+ 0.3V)

ESD Protection (Human Body Model) .............................>2000V
Current into Any Pin ............................................................10mA
Output Short-Circuit Duration.....................................Continuous
Continuous Power Dissipation (T

A

= +70°C)

5-Pin SC70 (derate 3.1mW/°C above +70°C) ..............245mW
5-Pin SOT23 (derate 7.1mW/°C above +70°C)............571mW

Operating Temperature Range .........................-55

°C to +125°C

Junction Temperature ......................................................+150

°C

Storage Temperature Range .............................-65

°C to +150°C

Lead Temperature (soldering, 10s) .................................+300

°C

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

T

A

= +20°C to +50°C

-2.0

0.6

+2.0

T

A

= 0°C to +70°C

-3.5

0.7

+3.5

T

A

= -10°C to +85°C

-5.0

1.0

+5.0

Temperature Error

V

CC

= +2.4V

T

A

= -20°C to -10°C

-6.0

1.5

+6.0

°C

Supply Voltage

V

CC

1.8

3.6

V

T

A

= +70°C

1000

T

A

= +80°C

500

Maximum Rate of Rise of Supply
Voltage (Note 2)

V

CC

< 2.8V

T

A

= +85°C

100

V/s

Supply Current

I

Q

No load

8

15

µA

Output Voltage

V

OUT

T

A

= 0°C

500

mV

Sensor Gain (Average Slope)

10

mV/°C

Maximum Capacitive Load

1

nF

Load Regulation

I

OUT

= -1.2µA to +20µA

0.15

0.2

°C/µA

Line Regulation

0.3

0.9

°C/V